Welcome to D-FAN !

Company News:
About Us
Product Categories

DONGGUAN XINGDONG ELECTRONICS CO., LTD.
Address:LiShi Industrial Zone, QiaoLi Village, ChangPing Town,DongGuan City, GuangDong 523586, China
Tel: +86-769-83660708
Fax: +86-769-83660718
Email: info@d-fan.com.cn
URL:/eng/
Chiefly Choice co.,Ltd.
Add: 3rd Floor, NO.340 Kangning Street, Xizhi City, Taipei, Taiwan
Tel: +886-2-2692-6816
Fax: +886-2-2692-7030
Email:  james@chiefly-choice.com
Website: www.chiefly-choice.com
XINGDONG Korea Company/ CHANG SHIN E&T
Add: #1113, Hanshin IT Tower,272,Digital-Ro, Guro-Gu, Seoul, Korea
Tel: +82-2-6093-6788 
Fax: +82-2-6093-8972
Phone: +82-10-6656-0330
E-mail: cs@csfan.co.kr
Website: www.csfan.co.kr
Contact:HONG GYOON KANG
Korea OEM business /JC International Inc.
Add: Bikeum B/D 3rd fl. Yangwharo 108, Mapo-Gu, Seoul. Korea
Tel: 82-2-3262800
Fax: 82-2-3260234
E-mail: fan1@jcint.co.kr/jylee@jcint.co.kr
Website: www.jcint.co.kr
Guangzhou Office
Tel: +86-20-85651751
Fax: +86-20-38669584
Office: Room 909Guaner Yongtai building,
           Congyun Road No.810,Baiyun District of Guangzhou,
           Guangdong,China
Add: 603#,NO.395 Tangdenan Rd, Tianhe District,
        Guangzhou, China

news

You are here:Home > news

Waterproof Cooling Fan Troubleshooting

Time:2015-1-9 Click:535Times

"Waterproof Cooling Fan" is controlled by the engine control unit, when the vehicle turn off power supply delay J271 still about 10 min, and then the engine determines the vehicle state assessment of the fan is running. However, after 10 min J271 engine flameout still supply unit to the cooling fan control bit is not normal. J271 cause engine stalling after 10min still pull for the following reasons: Ground wire and shorted wire on terminal 4 "Waterproof Cooling Fan"; the engine control unit inside the Ground; J271 own combination. Because in front of the engine control unit has been replaced and the J271, but the fault persists, so the focus of the investigation on the wire 4 terminals J271 whether the short to ground caused by the failure, then cut off the wire terminals 4, and the other with a fly line conductors treatment, symptoms disappear, thereby determining the above "Waterproof Cooling Fan" is a wire fault accident Ground terminal 4 on J271 due to failure to completely eliminate the fly line treatment after fixation.

DONGGUAN XINGDONG ELECTRONICS CO., LTD.

Tel: +86-769-83660708

Fax: +86-769-83660718

Email:info@d-fan.com.cn

URL: /eng/
 

Address:LiShi Industrial Zone, QiaoLi Village, ChangPing Town,DongGuan City, GuangDong 523586, China

Follow Us

Main Products: DC Fan|Cooling Fan|AC Fan|Axial Fan|Cross Flow Fan|Exhaust Fan|Blower Fan|DC Axial Fan|DC Cooling Fan

Copyright©2014, DONGGUAN XINGDONG ELECTRONICS CO., LTD., All Rights Reserved. Tel:+86-769-83660708,,Fax:+86-769-83660718 E-mail:info@d-fan.com.cn

XML 地图 | Sitemap 地图